Welcome to the FGIA Online Store, the new home for AAMA and IGMA publications.
  • Begin your search by entering information into the fields below.
  • Search by category, product code or keyword.
  • To see a list of all AAMA and IGMA publications, leave the product code and keyword fields blank.

Please read our simple purchasing instructions first to ensure a smooth transaction. We accept Visa, MasterCard, American Express and Discover. For detailed information on applicable fees and order processing, please review the FGIA Order Process.

For your convenience, the Publication Catalog includes a listing of all AAMA and IGMA technical documents.

Please contact FGIA for further assistance.

 

Check Out | Cart Details | New Search | Cancel Order

 


Results for 'All Categories' 

Important Notes:
- Member discount will be reflected after successful login on the Checkout screen.
- When documents share the same number, the title starting with an * is the most recent publication of that series.

*Airflow Through Integral Ventilating Systems/Devices
This document is intended as a guideline for architects, mechanical engineers, fabricators and owners using integral window ventilating systems/devices for supplemental natural ventilation.

Editorially revised

(AAMA TIR-A12-09)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Design of Exterior Shading Devices
This AAMA technical informational report presents design considerations for exterior shading devices. It should be used in conjunction with AAMA 514-16, "Standard Test Method for Static Loading and Impact on Exterior Shading Devices," in preparation of architectural drawings and specifications, shop drawings and structural calculations, and maintenance programs, to avoid some of the technical and practical issues that can arise from improper design or application of shading devices.

(AAMA TIR-A16-19)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Fenestration Anchorage Guidelines
This Technical Information Report is meant to be a companion document to AAMA 2501 and offer engineering rules and guidelines in the design of anchorage fasteners for windows and doors.

(AAMA TIR-A14-20)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Maximum Allowable Deflection of Framing Systems for Building Cladding Components at Design Wind Loads
This document provides suggested maximum deflection limits for building cladding framing systems which support glass or other similar brittle materials.

(AAMA TIR-A11-15)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Overview of Design Wind Load Determination for Fenestration Systems
This technical information report determines design wind loads on exterior fenestration and cladding systems using the national standards ASCE/SEI 7-16 and -22.

(AAMA TIR-A15-23)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Recommended Static Water Penetration Resistance Test Pressures in Non-Hurricane-Prone Regions of the United States
The purpose of this AAMA TIR is to provide guidance in regards to resistance to wind-driven rain penetration.

(AAMA TIR-A13-13)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Sound Control for Fenestration Products
This document was prepared for anyone who requires information on what sound is, how it is transmitted, how it is measured and how its transmission can be controlled. Although technical in nature, this document is organized to be useful to anyone from the window designer who is trying to meet an architect's sound control specification to a window salesman who just wants to help a customer understand how sound travels and what can be done to "cut down on the noise." Furthermore, this document will clarify and differentiate between the two methods of product classification, STC (Sound Transmission Class) and OITC (Outdoor-Indoor Transmission Class), and their appropriate use.

(AAMA TIR-A1-15)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Bundle)

*Structural Test Deflection and Permanent Deformation Gauge Placement for Fixed and Compression Seal Windows
The AAMA TIR-A18-21 describes the correct placement of deflection measurement devices, and calculations for determining deflection and permanent deformation when performing structural testing of fixed and compression seal products under uniform static air pressure difference per ASTM E330/E330M and/or AAMA/WDMA/CSA 101/I.S.2/A440.

(AAMA TIR-A18-21)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Structural Test Deflection and Permanent Deformation Gauge Placement for Horizontal and Vertical Sliding Windows and Sliding Doors
The intent of this Technical Information Report (TIR) is to establish criteria for deflection and permanent deformation gauge device locations in order to meet uniform deflection and structural load test specifications and requirements specific to horizontal and vertical sliding windows and doors.

(AAMA TIR-A19-22)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

*Structural Test Deflection and Permanent Deformation Gauge Placement for Single-Point Lock Side-Hinged Door Systems
The intent of this Technical Information Report (TIR) is to establish criteria for deflection and permanent deformation gauge device locations in order to meet uniform deflection and structural load test specifications and requirements specific to side-hinged exterior doors.

(AAMA TIR-A17-20)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Airflow Through Integral Ventilating Systems/Devices
This document is intended as a guideline for architects, mechanical engineers, fabricators and owners using integral window ventilating systems/devices for supplemental natural ventilation.
(AAMA TIR-A12-00)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Fenestration Anchorage Guidelines
This Technical Information Report is meant to be a companion document to AAMA 2501 and offer engineering rules and guidelines in the design of anchorage fasteners for windows and doors.

(AAMA TIR-A14-10)
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Maximum Allowable Deflection of Framing Systems for Building Cladding Components at Design Wind Loads
Specification provides guidance for the architect and specifier in selecting deflection limits for storefront and curtain wall applications.

(AAMA TIR-A11-04)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Overview of Design Wind Load Determination for Fenestration Systems
This technical information report determines design wind loads on exterior fenestration and cladding systems using the national standards ASCE/SEI 7-05 and -10.

(AAMA TIR-A15-14)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Recommended Static Water Test Pressures in Non-Hurricane-Prone Regions of the United States
The purpose of this AAMA TIR is to provide guidance in regards to resistance to wind-driven rain penetration.

(AAMA TIR-A13-09)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Sound Control for Fenestration Products
This document was prepared for anyone who requires information on what sound is, how it is transmitted, how it is measured and how its transmission can be controlled. Although technical in nature, this document is organized to be useful to anyone from the window designer who is trying to meet an architect's sound control specification to a window salesman who just wants to help a customer understand how sound travels and what can be done to "cut down on the noise." Furthermore, this document will clarify and differentiate between the two methods of product classification, STC (Sound Transmission Class) and OITC (Outdoor-Indoor Transmission Class), and their appropriate use.

(AAMA TIR-A1-04)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Sound Control for Fenestration Products
This document was prepared for anyone who requires information on what sound is, how it is transmitted, how it is measured and how its transmission can be controlled. Although technical in nature, this document is organized to be useful to anyone from the window designer who is trying to meet an architect's sound control specification to a window salesman who just wants to help a customer understand how sound travels and what can be done to "cut down on the noise." Furthermore, this document will clarify and differentiate between the two methods of product classification, STC (Sound Transmission Class) and OITC (Outdoor-Indoor Transmission Class), and their appropriate use.

(AAMA TIR-A1-02)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Windloads on Components and Cladding for Buildings Less than 90 Feet Tall
Windloads on Components and Cladding for Buildings Less than 90 Feet Tall.

(AAMA TIR-A10-97)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!
  Qty:     Download   (Per Copy)

Windloads on Components and Cladding for Buildings Less Than 90 Feet Tall
ARCHIVED DOCUMENT

This publication simplifies the calculation procedures of structural windload requirements detailed in ASCE 7-95. (AAMA TIR-A10-00)

Please be aware that there is a newer version of this document available for purchase
Member Rates: Download - $20.00
Non-Member Rates: Download - $60.00
Click to add this item to your cart!